Portable stations
The independent portable stations are used for fast employment. They are erected and ready for measuring in approx. 20 minutes. The measured variables are temperature, humidity, air pressure, precipitation, wind velocity and direction. A typical operational area is the investigation of convective systems.
Fig.1: Portable stations |
Assembly portable station |
Quantity | Device | Type | Manufacturer | Variable | Measuring Height |
1 | Sonic anemometer |
81000 | Young | wind vector, temperature, momentum flux, sensible heat flux |
4 m |
1 | Barometer | 61202V | Young | air pressure (p) | 1 m |
1 | Temperature and humidity sensor |
MP100 | Rotronic | air temperature, relative humidity |
2 m |
1 | Rain gauge | 52202 | Young | precipitation | 1 m |
1 | elektronic compass |
32500 | Young | orientation |